YC-TI-PS-0005 | Ceyear 87245

YC-TI-PS-0005 | Ceyear 87245 Series LAN Average Power Sensor

Price on request

Request a quote

The 87245 series measures average power of CW, pulse-modulated and vector-modulated signals over LAN. Models B/D/H/L have different frequency and power ranges and require PoE for power and communication, supporting remote monitoring and automated testing.

LAN power sensor series appearance reference showing multiple models, not an included set. The supplied model and connector are defined in the quotation.

Models and measurement ranges

Manufacturer modelFrequency rangePower measurement rangePower measurement accuracy
87245B8 kHz–8 GHz−70…+26 dBm±0.20 dB
87245D10 MHz–18 GHz−70…+26 dBm±0.20 dB
87245H10 MHz–50 GHz−65…+23 dBm±0.25 dB
87245L50 MHz–67 GHz−60…+23 dBm±0.33 dB

Accuracy conditions

Accuracy conditions: −40…+20 dBm for 87245B/H, −45…+20 dBm for D and −20…+20 dBm for L; DUT SWR<1.20 and averaging count 32. The full measurement range is not the interval for the stated accuracy.

Maximum VSWR

Manufacturer modelFrequency intervalMaximum VSWR
87245B8 kHz≤f≤8 GHz1.20
87245D10 MHz≤f≤6 GHz1.20
87245D6 GHz<f≤18 GHz1.26
87245H10 MHz≤f≤6 GHz1.16
87245H6 GHz<f≤16 GHz1.24
87245H16 GHz<f≤26.5 GHz1.35
87245H26.5 GHz<f≤40 GHz1.41
87245H40 GHz<f≤50 GHz1.48
87245L50 MHz≤f≤6 GHz1.20
87245L6 GHz<f≤16 GHz1.35
87245L16 GHz<f≤26.5 GHz1.45
87245L26.5 GHz<f≤40 GHz1.55
87245L40 GHz<f≤67 GHz1.68

Connection and core functions

Power and communicationCompatible PoE connection required
Power meter compatibilityNot compatible with the 2439D microwave power meter
Remote measurement distanceUp to 60 m with a compatible PoE connection and suitable network cable
  • 8 kHz–67 GHz is the combined series coverage, not the range of every model.
  • Average-power measurement does not include the peak and pulse-envelope functions of the 87246 series.

Options and quotation

PoE switch 87240-H01 and 1.5/3/5/15/30/60 m shielded Category 6 cables are options; the switch is not included by default. Specify model-specific -H12 English options, report and extended-warranty requirements when requesting a quote. Provide model, signal type, power range, network environment, accessories and quantity. Scope of supply and delivery schedule are defined in the quotation.

Request a quote