YC-TI-PS-0002 | Ceyear 87235

YC-TI-PS-0002 | Ceyear 87235 Series USB Average Power Sensor

Price on request

Request a quote

The 87235 series measures average power of CW, pulse-modulated and vector-modulated signals via USB 2.0. Eight models cover different frequency and power requirements; the 87235DG provides a −50…+44 dBm measurement range.

Series appearance reference showing multiple models. It does not imply that a set of sensors is included. The supplied model and connector are defined in the quotation.

Models and measurement ranges

Manufacturer modelFrequency rangePower measurement rangePower measurement accuracy
87235B8 kHz–8 GHz−70…+26 dBm±0.20 dB
87235C10 MHz–8 GHz−60…+23 dBm±0.20 dB
87235D10 MHz–18 GHz−70…+26 dBm±0.20 dB
87235DG10 MHz–18 GHz−50…+44 dBm±0.19 dB (10 MHz≤f≤8 GHz); ±0.23 dB (8 GHz<f≤18 GHz)
87235F10 MHz–33 GHz−65…+26 dBm±0.23 dB
87235FA10 MHz–40 GHz−65…+26 dBm±0.24 dB
87235H10 MHz–50 GHz−65…+23 dBm±0.25 dB
87235L50 MHz–67 GHz−60…+23 dBm±0.33 dB

Accuracy and conditions

Accuracy conditions: −40…+20 dBm for 87235B/C/FA/H; −45…+20 dBm for D/F; −20…+20 dBm for L; −20…+44 dBm for DG. DUT SWR<1.20 and averaging count 128. Account for zero-setting and noise effects at low power.

Maximum VSWR

Manufacturer modelFrequency intervalMaximum VSWR
87235B8 kHz≤f≤8 GHz1.20
87235C10 MHz≤f≤8 GHz1.20
87235D10 MHz≤f≤6 GHz1.20
87235D6 GHz<f≤18 GHz1.26
87235DG10 MHz≤f≤8 GHz1.20
87235DG8 GHz<f≤12.4 GHz1.30
87235DG12.4 GHz<f≤18 GHz1.41
87235F10 MHz≤f≤6 GHz1.16
87235F6 GHz<f≤16 GHz1.24
87235F16 GHz<f≤26.5 GHz1.38
87235F26.5 GHz<f≤33 GHz1.41
87235FA10 MHz≤f≤6 GHz1.15
87235FA6 GHz<f≤16 GHz1.25
87235FA16 GHz<f≤26.5 GHz1.40
87235FA26.5 GHz<f≤40 GHz1.45
87235H10 MHz≤f≤6 GHz1.16
87235H6 GHz<f≤16 GHz1.24
87235H16 GHz<f≤26.5 GHz1.35
87235H26.5 GHz<f≤40 GHz1.41
87235H40 GHz<f≤50 GHz1.48
87235L50 MHz≤f≤6 GHz1.20
87235L6 GHz<f≤16 GHz1.35
87235L16 GHz<f≤26.5 GHz1.45
87235L26.5 GHz<f≤40 GHz1.55
87235L40 GHz<f≤67 GHz1.68
  • +44 dBm is the 87235DG measurement limit, not a limit for other models or a damage rating for the whole family.
  • Average-power measurement of modulated signals does not imply the pulse-envelope and peak measurement functions of the 87236 series.

Options and quotation

English labels, manuals and software are model-specific -H12 options. Calibration reports and extended-warranty services are quoted separately, not assumed included. Specify model, signal type, power range, connector needs, accessories and quantity. Scope of supply and delivery schedule are defined in the quotation.

Request a quote