YC-TI-MUL-0002 | Ceyear 82401/06

YC-TI-MUL-0002 | Ceyear 82401/06 Series Millimeter-Wave Frequency Multiplier Module

Price on request

Request a quote

The 82401/06 series multiplies the output of compatible signal generators into model-specific bands across 50–1100 GHz. It uses standard waveguide outputs and a 15 V power adapter, with fixed saturated-power output for millimeter-wave and terahertz signal generation.

82401/06 series appearance reference. Port layout may vary with band module; the supplied model and waveguide are defined by the configuration table.

Models and frequency bands

Output power specifications are measured at 25±5 °C and apply to the corresponding model.

Manufacturer modelOutput frequencyInput frequencyMultiplierOutput waveguideSaturated output power
8240650–75 GHz12.5–18.8 GHz4WR15≥+13 dBm
82401N60–90 GHz10.0–15.0 GHz6WR12≥+11 dBm
82406A75–110 GHz12.5–18.4 GHz6WR10≥+10 dBm
82401QA90–140 GHz10.0–15.6 GHz9WR8.0≥+5 dBm
82406B110–170 GHz9.1–14.2 GHz12WR6.5≥+2 dBm
82406C170–220 GHz14.1–18.4 GHz12WR5.1≥−2 dBm
82401SA170–260 GHz9.4–14.5 GHz18WR4.3≥−6 dBm
82406D220–325 GHz12.2–18.1 GHz18WR3.4≥−8 dBm
82401TA260–400 GHz9.6–14.9 GHz27WR2.8≥−12 dBm
82406E325–500 GHz9.0–13.9 GHz36WR2.2≥−18 dBm
82401U500–750 GHz10.4–15.7 GHz48WR1.5≥−25 dBm
82401V750–1100 GHz10.4–15.3 GHz72WR1.0≥−33 dBm

Technical specifications

Output modeFixed saturated-power output; no levelled-power output
Drive signal power+5…+10 dBm; frequency within the selected model input range
RF drive input connector3.5 mm female
Power supply15 V power adapter
Power consumption≤30 W
Weight≤5 kg

Usage and ordering

  • 50–1100 GHz is the combined coverage of twelve models, not continuous full-range coverage by one module.
  • Levelled-power output is not supported. Programmable levelling capabilities of the 1400 series do not apply to this series.
  • Saturated output power specifications are measured at 25±5 °C. Use the input frequency range and output waveguide specified for the selected model.
  • 82406-JC, 82401N-JC and 82406A-JC are manufacturer test-service options with a test report; they are not automatically included in every quotation.

Quotation and delivery

Specify the output band, compatible signal generator model, required output power, waveguide interface and quantity. Band modules, accessories, test services and delivery schedule are defined in the quotation.

Request a quote