4457H 系列四通道配置实物示例

YC-TI-OSC-0003 | 4457H Series Digital Oscilloscope

Price on request

Request a quote

Product overview

Ceyear 4457H digital oscilloscopes provide 1–4 GHz bandwidth, standard 12-bit vertical resolution and standard 1 Gpts memory with all channels enabled. Model-dependent maximum sampling reaches 20 GSa/s with half the channels enabled and 10 GSa/s with all channels enabled. Logic analysis, function generation and analysis modules are optional.

Key functions

  • Standard 12-bit vertical resolution provides 4096 quantization levels; high-resolution mode is supported.
  • Standard 1 Gpts memory with all channels enabled; hardware-based zoom and waveform detail inspection.
  • Remote display and operation using the oscilloscope display client over LAN.

Models and core specifications

Manufacturer modelBandwidth (50 Ω)Sample rate (half / all channels)Analog channels
4457EH1 GHz10 / 5 GSa/s4; optional 8-channel configuration
4457FH2 GHz10 / 5 GSa/s4; optional 8-channel configuration
4457GH3 GHz10 / 5 GSa/s4; optional 8-channel configuration
4457KH4 GHz20 / 10 GSa/s4
ParameterSpecification
Standard memory depth1 Gpts (all channels)
Vertical resolution12 bit; 16 bit in high-resolution mode
Waveform capture rate700,000 waveforms/s
Display15.6-inch capacitive touchscreen, 1920×1080
Input / output interfacesUSB 3.0, USB 2.0, LAN, DP, VGA
Dimensions (W×H×D)(426.0±4)×(310.3±2.5)×(200.0±2.5) mm
Weight≤15 kg

Configuration details and accessories

Function options
Option modelFunction and specifications
4457-H01Logic analysis: 16 digital channels, 2.5 GSa/s, 160 Mpts memory.
4457-H02Function generator: 2 channels, 50 MHz bandwidth, 200 MSa/s; predefined and arbitrary waveforms.
4457-S01Mask testing: ITU-T, ANSI T1.102, USB and user-created masks.
4457-S02Power measurement and analysis: power quality, switching loss, harmonics, ripple and modulation.
4457-S03Bode analysis: control-loop frequency response and feedback-system stability.
4457-S04–4457-S16Bus triggering and analysis: I²C, SPI, CAN, FlexRay, LIN, RS232, USB, Audio, MIL-STD-1553, ARINC429, CAN FD, SENT and Manchester; select options by protocol.
4457-S20Eye-diagram analysis: eye height, eye width, zero/one levels, Q factor and related measurements.
4457-S21Jitter analysis: histogram, trend, spectrum and bathtub curve; time-interval error (TIE) display.
4457-S22Real-time spectrum analysis: DC to oscilloscope bandwidth; maximum real-time analysis bandwidth 320 MHz, FFT refresh rate 400,000/s.
Hardware options
Model / itemDescription
4457-H03Solid-state drive
4457-H04Rack-mount kit
4457-H05Aluminum-alloy transport case
4457-H07BNC-to-SMA cable kit
Probe optionsSelect from the oscilloscope probe options according to the application
Bandwidth-upgrade options
Upgrade modelApplicable configurationBandwidth upgrade
4457-H92-10T204-channel EH1 GHz → 2 GHz
4457-H92-10T304-channel EH1 GHz → 3 GHz
4457-H92-20T304-channel FH2 GHz → 3 GHz
4457-H94-10T208-channel EH1 GHz → 2 GHz
4457-H94-10T308-channel EH1 GHz → 3 GHz
4457-H94-20T308-channel FH2 GHz → 3 GHz
Supplied accessories
AccessoryQuantity / description
P9500A high-impedance probes4-channel configuration: 4; 8-channel configuration: 8
Power cable1 standard three-core power cable
User manual1 copy
Programming manual1 copy

Application and selection notes

Sample rate depends on active channels: EH/FH/GH provide 10 GSa/s with half the channels enabled and 5 GSa/s with all channels enabled; KH provides 20 GSa/s with half and 10 GSa/s with all channels enabled. Select according to the required channel count.

The 8-channel configuration, logic analysis, function generation and analysis modules are optional. The 16-bit specification applies only to high-resolution mode; standard acquisition resolution is 12 bit.

This page covers the 4457H series. Function options use the listed shared ordering codes such as 4457-H01/H02 and 4457-S01…S22. Select H92/H94 bandwidth upgrades according to EH/FH and four/eight-channel configurations.

The image shows a four-channel 4457H series configuration; actual channel count and options are defined by the quotation.

Ordering and delivery

Typical MOQ is 1 unit; configuration, probes and delivery are subject to the formal quotation.

Request a configuration quote