Ceyear 4457 digital oscilloscopes offer 1–5 GHz bandwidth, model-dependent 10/20 GSa/s maximum sampling on all channels and standard 2 Gpts memory. Optional eight-channel E/F/G configurations and logic, waveform-generation, bus, eye, jitter and real-time spectrum functions are available.

Key functions

  • The model-specific maximum sample rate and standard 2 Gpts memory are maintained with all channels enabled; hardware-based zoom is supported.
  • Hardware parameter measurement supports simultaneous display of 20 measurements, statistics and automatic cursor tracking.
  • Remote display and operation via the oscilloscope display client over LAN.

Models and core specifications

Manufacturer modelBandwidth (50 Ω)Maximum sample rate (all channels)Analog channels
4457E1 GHz10 GSa/s4; optional 8-channel configuration
4457F2 GHz10 GSa/s4; optional 8-channel configuration
4457G3 GHz10 GSa/s4; optional 8-channel configuration
4457K4 GHz20 GSa/s4
4457L5 GHz20 GSa/s4
ParameterSpecification
Standard memory depth2 Gpts (all channels)
Vertical resolution8 bit; 16 bit in high-resolution mode
Waveform capture rate1.2 million waveforms/s
Display15.6-inch capacitive touchscreen, 1920×1080
Input / output interfacesUSB 3.0, USB 2.0, LAN, DP, VGA
Dimensions (W×H×D)(426.0±4)×(310.3±2.5)×(200.0±2.5) mm
Weight≤15 kg

Configuration details and accessories

Function options
Option modelFunction and specifications
4457-H01Logic analysis: 16 digital channels, 2.5 GSa/s, 160 Mpts memory.
4457-H02Function generator: 2 channels, 50 MHz bandwidth, 200 MSa/s; predefined and arbitrary waveforms.
4457-S01Mask testing: ITU-T, ANSI T1.102, USB and user-created masks.
4457-S02Power measurement and analysis: power quality, switching loss, harmonics, ripple and modulation.
4457-S03Bode analysis: control-loop frequency response and feedback-system stability.
4457-S04–4457-S16Bus triggering and analysis: I²C, SPI, CAN, FlexRay, LIN, RS232, USB, Audio, MIL-STD-1553, ARINC429, CAN FD, SENT and Manchester; select options by protocol.
4457-S20Eye-diagram analysis: eye height, eye width, zero/one levels, Q factor and related measurements.
4457-S21Jitter analysis: histogram, trend, spectrum and bathtub curve; time-interval error (TIE) display.
4457-S22Real-time spectrum analysis: DC to oscilloscope bandwidth; maximum real-time analysis bandwidth 320 MHz, FFT refresh rate 400,000/s.
Hardware options
Model / itemDescription
4457-H03Solid-state drive
4457-H04Rack-mount kit
4457-H05Aluminum-alloy transport case
4457-H07BNC-to-SMA cable kit
Probe optionsSelect from the oscilloscope probe options according to the application
Bandwidth-upgrade options
Upgrade modelChannel configurationBandwidth upgrade
4457-H91-10T204 channels1 GHz → 2 GHz
4457-H91-10T304 channels1 GHz → 3 GHz
4457-H91-20T304 channels2 GHz → 3 GHz
4457-H93-10T208 channels1 GHz → 2 GHz
4457-H93-10T308 channels1 GHz → 3 GHz
4457-H93-20T308 channels2 GHz → 3 GHz
Supplied accessories
AccessoryQuantity / description
P9500A high-impedance probes4-channel configuration: 4; 8-channel configuration: 8
Power cable1 standard three-core power cable
User manual1 copy
Programming manual1 copy

Application and selection notes

The 8-channel configuration, logic analysis, function generation and analysis modules are optional. Specify the mainframe model, channel count and options for a quotation. The 16-bit high-resolution mode is not the standard acquisition resolution.

This page covers the 4457 series only. The 4457H and 4457M are separate product series. Select bandwidth upgrades according to the listed configurations; do not assume other models support the same upgrades.

The image shows an eight-channel 4457 series configuration; actual channels and options are defined by the quotation.

Ordering and delivery

Typical MOQ is 1 unit; configuration, probes and delivery are subject to the formal quotation.

Request a configuration quote