YC-TI-NFA-0001 | Ceyear 3987P

YC-TI-NFA-0001 | Ceyear 3987 Series Noise Figure Analyzer

Price on request

Request a quote

The 3987 series measures noise figure and gain of amplifiers, up/downconverters and multistage receiver chains. Seven models cover 10 MHz to 8, 18, 26.5, 40, 50, 67 or 110 GHz. Features include an 11.6-inch touchscreen, loss compensation, an uncertainty calculator and limit testing. Frequency range and input connector depend on selected model.

3987P appearance reference; connectors and configuration of other models follow their respective specifications.

Models and selection parameters

ModelFrequency rangeInput interfaceInput VSWRInstrument noise figure
3987B10 MHz–8 GHz3.5 mm (M)≤1.90:1 (10 MHz ≤ f ≤ 8 GHz)<9.0 dB (10 MHz ≤ f ≤ 8 GHz)
3987D10 MHz–18 GHz3.5 mm (M)≤1.90:1 (10 MHz ≤ f ≤ 8 GHz); ≤2.20:1 (8 GHz < f ≤ 18 GHz)<9.0 dB (10 MHz ≤ f ≤ 8 GHz); <8.5 dB (8 GHz < f ≤ 18 GHz)
3987E10 MHz–26.5 GHz3.5 mm (M)≤1.90:1 (10 MHz ≤ f ≤ 8 GHz); ≤2.20:1 (8 GHz < f ≤ 26.5 GHz)<9.0 dB (10 MHz ≤ f ≤ 8 GHz); <9.0 dB (8 GHz < f ≤ 26.5 GHz)
3987F10 MHz–40 GHz2.4 mm (M)≤1.90:1 (10 MHz ≤ f ≤ 8 GHz); ≤2.20:1 (8 GHz < f ≤ 40 GHz)<9.0 dB (10 MHz ≤ f ≤ 8 GHz); <10.0 dB (8 GHz < f ≤ 40 GHz)
3987H10 MHz–50 GHz2.4 mm (M)≤1.90:1 (10 MHz ≤ f ≤ 8 GHz); ≤2.20:1 (8 GHz < f ≤ 40 GHz); ≤2.50:1 (40 GHz < f ≤ 50 GHz)<9.0 dB (10 MHz ≤ f ≤ 8 GHz); <10.0 dB (8 GHz < f ≤ 40 GHz); <12.0 dB (40 GHz < f ≤ 50 GHz)
3987L10 MHz–67 GHz1.85 mm (M)≤1.90:1 (10 MHz < f ≤ 8 GHz); ≤2.20:1 (8 GHz < f ≤ 50 GHz); ≤2.50:1 (50 GHz < f ≤ 67 GHz)<10.0 dB (10 MHz ≤ f ≤ 8 GHz); <16.0 dB (8 GHz < f ≤ 50 GHz); <14.0 dB (50 GHz < f ≤ 67 GHz)
3987P10 MHz–110 GHz1.0 mm (M)—<18.5 dB (10 MHz ≤ f ≤ 50 GHz); <20.0 dB (50 GHz < f ≤ 110 GHz)

Measurement and common specifications

ParameterSpecification
Frequency-reference accuracy± <2×10⁻⁷
Tuning accuracy (≤8 GHz)± <90 kHz (10 MHz ≤ f ≤ 8 GHz)
Tuning accuracy (>8 GHz)± <300 kHz (8 GHz < f ≤ 110 GHz)
Noise-figure range (ENR 12–17 dB)0–30 dB (ENR 12–17 dB)
Noise-figure range (ENR 20–22 dB)0–35 dB (ENR 20–22 dB)
Noise-figure uncertainty (0–30 dB)± <0.10 dB (0–30 dB)
Noise-figure uncertainty (0–35 dB)± <0.15 dB (0–35 dB)
Gain measurement range−20 to +40 dB
Gain measurement uncertainty± <0.17 dB
Jitter without averaging<0.15 dB
Noise-source drive voltage: off<1.0 V
Noise-source drive voltage: on+28.0 V ±0.20 V
Touchscreen size (inches)11.6
Noise-source drive interfaces28 V / I²C / USB
Input impedance50 Ω
Maximum power consumption250 W
AC supply110–220 V AC, 50/60 Hz
Overall W×H×D(474.6±4) × (193±2.5) × (559.5±4) mm
Nominal W×H×D(426±4) × (177±2.5) × (450±4) mm
Weight≤25 kg
Operating temperature0 to +40 °C
Storage temperature−40 to +70 °C

Options and services

Option codeDescriptionApplicable model
3987-H05Optional aluminum transport case3987B/D/E/F/H/L/P
3987-H97Optional rack-mount kit3987B/D/E/F/H/L/P
3987-H98Optional English panel, manual, interface and operating system3987B/D/E/F/H/L/P
3987B-JLOptional calibration service and report3987B
3987D-JLOptional calibration service and report3987D
3987E-JLOptional calibration service and report3987E
3987F-JLOptional calibration service and report3987F
3987B-EWT1Optional one-year warranty extension after standard warranty3987B
3987D-EWT1Optional one-year warranty extension after standard warranty3987D
3987E-EWT1Optional one-year warranty extension after standard warranty3987E
3987F-EWT1Optional one-year warranty extension after standard warranty3987F
3987H-EWT1Optional one-year warranty extension after standard warranty3987H
3987L-EWT1Optional one-year warranty extension after standard warranty3987L
3987P-EWT1Optional one-year warranty extension after standard warranty3987P

Applications and supply

  • M means male. ENR means excess noise ratio. Select the actual model range and connector rather than applying the series maximum to every model.
  • Instrument noise figure is not the DUT noise-figure measurement range. Apply the stated frequency bands and ENR conditions.
  • No input VSWR value for the 3987P is stated in this table. A dash does not mean zero reflection or error.
  • Single- and double-sideband modes are supported. Extended system-downconversion measurements require a suitable external mixer and LO; they do not extend the native analyzer range by themselves.
  • Fixed or tabulated compensation covers losses before and after the DUT. Automatic ENR loading and temperature correction require the appropriate smart noise source and interface.
  • Steady-state supply-voltage tolerance is 10% of nominal and frequency tolerance is 5% of nominal. Nominal dimensions exclude handles, feet, rear frame, connectors and other protrusions.
  • English package, case, rack kit and services are optional, not all included by default. Extended warranty excludes calibration. Confirm service coverage and shipping terms in the quotation.

Catalog supplied accessories are a standard three-core power cord, user manual and product conformity certificate. Provide DUT band, gain/noise-figure ranges, noise-source type, interface, report requirements and quantity to confirm model, options, calibration method and supplied items.

Request a quote