1769 系列程控直流电源实物参考图(1769AD)

YC-TI-PSU-0004 | 1769 Series Programmable DC Power Supply

Price on request

Request a quote

Product overview

Ceyear 1769 high-power programmable DC supplies offer 5/10/15 kW models, up to 500 V, and model-dependent maximum currents of 30/60/90 A. A 3U chassis provides autoranging CV/CC/CP operation, remote sensing and parallel-system support for development, production and high-power supply testing.

Key functions

  • Autoranging output supports constant-voltage, constant-current and constant-power modes.
  • Supports voltage, current and power measurements plus remote voltage sensing.
  • Overvoltage, overcurrent and overtemperature protection.
  • LAN, USB and GPIB remote control plus analog programming.
  • Up to seven power supplies of the same model can operate in parallel; a combination of 15 kW models can form an output system exceeding 100 kW.

Models and core specifications

Manufacturer modelMaximum powerMaximum voltageMaximum currentWeight
1769AD5 kW500 V30 A≤20 kg
1769BD10 kW500 V60 A≤28.2 kg
1769CD15 kW500 V90 A≤35.5 kg
Parameter1769AD1769BD1769CD
Voltage programming accuracy≤500 mV≤500 mV≤500 mV
Voltage measurement accuracy≤500 mV≤500 mV≤500 mV
Current programming accuracy≤60 mA≤120 mA≤180 mA
Current measurement accuracy≤60 mA≤120 mA≤180 mA

Detailed specifications and accessories

Constant-voltage output ripple and noise
Parameter1769AD1769BD1769CD
CV RMS (20 Hz–300 kHz)70 mVrms70 mVrms70 mVrms
CV peak-to-peak (20 Hz–20 MHz)350 mVp-p350 mVp-p350 mVp-p
Load regulation and output response
Parameter1769AD1769BD1769CD
Load regulation: voltage250 mV250 mV250 mV
Load regulation: current45 mA90 mA135 mA
Transient response time (settling band: 1% of rated voltage)≤1.5 ms≤1.5 ms≤1.5 ms
Voltage rise time (loaded)≤30 ms≤30 ms≤30 ms
Voltage fall time (loaded)≤80 ms≤80 ms≤80 ms
Voltage fall time (unloaded)≤10 s≤10 s≤10 s
Input, environment, interfaces and mechanical specifications
ParameterSpecification
Input voltage range360–440 VAC
Input wiring systemThree-phase, 3W+PE
Input frequency45–65 Hz
Operating temperature0°C–45°C
Storage temperature−20°C–70°C
Relative humidity≤80%, non-condensing
Altitude≤2000 m
Remote-control interfacesLAN (10/100 Base-T) ×1; USB 2.0 Type-B ×1; GPIB ×1
Analog programming input range0–5 V or 0–10 V
Chassis height3U
External dimensions (W×H×D)(483±4.0)×(137.5±2.5)×(717±4.0) mm
Nominal dimensions (W×H×D)(483±4.0)×(133±2.5)×(701.5±4.0) mm; excluding feet, output-terminal guard and handles
Power factor≥0.99
Supplied accessories
AccessoryQuantity / description
Three-phase AC power cable1
DC output-terminal guard1
Remote-sense terminal1
Current-sharing terminal1
User manualElectronic copy
Product conformity certificateAffixed to the product

Application and selection notes

Maximum power, voltage and current are individual limits, not simultaneous operating points. Autoranging output is limited by the rated power of the selected model.

Ripple RMS and peak-to-peak values use different measurement bandwidths: 20 Hz–300 kHz and 20 Hz–20 MHz. Rise/fall times refer to 10%→90% / 90%→10% of rated voltage; distinguish loaded and unloaded conditions.

Use same-model supplies for parallel systems according to the manufacturer configuration, including current sharing, wiring and protection. Actual combined power and input requirements are defined by the system configuration.

Image is a 1769AD configuration reference; delivered model, parallel-system solution and accessories are defined by the quotation.

Ordering and delivery

Typical MOQ is 1 unit; configuration and delivery are subject to the formal quotation.

Request a configuration quote