1763 电源阵列模拟器正面实物图

YC-TI-PSA-0001 | 1763 Solar Array Simulator

Price on request

Request a quote

Product overview

Ceyear 1763 simulates the I–V output characteristics of satellite solar panels and solar-cell arrays, with curve simulation, list output, constant-voltage and constant-current modes. A two-module mainframe delivers up to 1200 W, with four standard module types and GPIB, LAN and USB remote-control interfaces.

Key functions

  • Supports I–V curve simulation, curve-table/list output and rapid curve transitions.
  • Four standard module types are available; rated power reaches 600 W per module and 1200 W for a two-module mainframe.
  • Constant-voltage, constant-current and series/parallel operation support satellite power-system and photovoltaic supply-simulation testing.
  • SCPI compatibility with GPIB, LAN and USB interfaces.

Models and core specifications

Manufacturer module modelFixed-mode voltageFixed-mode currentMaximum simulation open-circuit voltage
DC1763010–60 V0–8.5 A65 V
DC1763020–120 V0–5 A130 V
DC1763030–157 V0–3.8 A170 V
DC1763040–69.2 V0–8 A75 V
Parameter60 V module120 V module157 V module75 V module
Simulation/list: maximum power510 W600 W596 W553.6 W
Simulation/list: maximum open-circuit voltage65 V130 V170 V75 V
Simulation/list: voltage at maximum power point60 V120 V157 V69.2 V
Simulation/list: maximum short-circuit current8.5 A5 A3.8 A8 A
Simulation/list: current at maximum power point8.5 A5 A3.8 A8 A
Fixed mode: voltage0–60 V0–120 V0–157 V0–69.2 V
Fixed mode: current0–8.5 A0–5 A0–3.8 A0–8 A

Detailed specifications and accessories

Output ripple and noise
Parameter60 V module120 V module157 V module75 V module
Voltage: simulation/list mode20 mVrms / 125 mVp-p24 mVrms / 195 mVp-p32 mVrms / 250 mVp-p21 mVrms / 136 mVp-p
Voltage: fixed mode (CV)24 mVrms / 150 mVp-p30 mVrms / 150 mVp-p40 mVrms / 195 mVp-p25 mVrms / 150 mVp-p
Current: simulation/list mode4 mArms / 32 mAp-p4 mArms / 32 mAp-p4 mArms / 32 mAp-p4 mArms / 32 mAp-p
Current: fixed mode (CC)2.5 mArms / 19 mAp-p2.5 mArms / 19 mAp-p2.5 mArms / 19 mAp-p2.5 mArms / 19 mAp-p
Programming and readback accuracy (23°C±5°C)
Parameter60 V module120 V module157 V module75 V module
Programming: fixed-mode voltage0.075% + 25 mV0.075% + 50 mV0.075% + 65 mV0.075% + 29 mV
Programming: current0.20% + 20 mA0.20% + 10 mA0.20% + 8 mA0.20% + 19 mA
Readback: voltage0.08% + 25 mV0.08% + 50 mV0.08% + 65 mV0.08% + 29 mV
Readback: current0.20% + 20 mA0.20% + 10 mA0.20% + 8 mA0.20% + 19 mA
Fixed-mode load/line regulation and response
Parameter60 V module120 V module157 V module75 V module
Load regulation (23°C±5°C): CV2 mV2 mV3 mV2 mV
Load regulation (23°C±5°C): CC1 mA1 mA1 mA1 mA
Line regulation (23°C±5°C): CV2 mV1 mV2 mV2 mV
Line regulation (23°C±5°C): CC1 mA1 mA1 mA1 mA
Output capacitance<100 nF<50 nF<50 nF<100 nF
Voltage rise/fall time<8 ms<8 ms<8 ms<8 ms
Mainframe input, mechanical and interface specifications
ParameterSpecification
Maximum mainframe output power1200 W; two-module configuration, depending on selected modules
AC input voltage220 VAC ±10%
Input frequency50 Hz ±5%
AC input current / maximum input power16 Arms / 2200 VA
External dimensions (W×H×D)(438±4)×(88±0.8)×(640±4) mm
Nominal dimensions (W×H×D)(426±2)×(88±0.8)×(601±2) mm; excluding handles, connectors, buttons and screws
WeightMainframe: 12 kg; module: 4 kg
Remote control and interfacesSCPI; GPIB, LAN, USB
Supplied accessories
AccessoryDescription
Power-cable assemblyStandard three-core power cable
User manualElectronic copy
Product conformity certificateAffixed to the product
Output connector and shorting linkFor output connections

Application and selection notes

Simulation/list open-circuit voltage differs from the fixed-mode voltage limit. Select modules for the required operating mode. In series operation, current must not exceed the module rating; parallel modules must use the same output voltage.

Voltage ripple/noise is specified with a resistive load, ungrounded or grounded output, over 20 Hz–20 MHz. Readback accuracy refers to front-panel or GPIB readings relative to actual output. In the accuracy expressions, the percentage term applies to the corresponding voltage/current value, plus the fixed error term.

Follow manufacturer wiring requirements for remote sensing. Use twisted-pair or shielded sense leads; ground one shield end at the output connector and leave the other end open. Do not use the shield as a sense conductor.

Image shows an example 1763 mainframe configuration; module combination and supplied accessories are defined by the quotation.

Ordering and delivery

Typical MOQ is 1 unit; configuration and delivery are subject to the formal quotation.